UL Cable Vertical-Tray Flammability Testing Equipment

Short Description:

Apply to check the vertical-tray fire test for determining values of cable flame propagation and smoke release when the cables are subjected to a flaming ignition source. (It is nothing to the purpose of cables, such as the electric power, telecommunications etc.)


  • Min.Order Quantity: 1 unit
  • Price: Negotiable
  • Package : Plywood Case
  • Model: SL-7601S
  • Standards: UL1685-2007, UL2556-2007
  • Product Detail

    Product Tags

    UL Cable Vertical-Tray Flammability Testing Equipment

    Product parameter of the UL Cable Vertical-Tray Flammability Test

     Test room  Fire resistance bricks for walls and which density is 1698kg/m3, Interface spray black paint, and the outer size of the room is W2438×D2438×H3353mm
     Door  Stainless steel frame and wired-glass door, the overall size is W0.9× H2.0m
     Smoke collection hood  Which made by stainless steel, each side is to be sloped 400, the hood as a cube and each side length is 914mm, there is a dust mesh under the hood and each side length is 610mm
     Observation window  Which as a square and each side length is 457mm, 1295mm distance from the lower side of the window to floor, 1143mm distance from right of the window to the wall
     Air inlets which size are 559×343mm, 914×305mm, 2438×343mm
     Exhaust duct  L9000×φ406mm, install it at the centered in on the right side of the cube hood
     Cable tray  H2400mm, the rundle as a square which size is L305×W25×D25, and both rundles distance is 299mm
     Burner  L341mm×D30mm with 242 holes
     Gas flux  13.2L/min, 0.1Mpa for gas pressure
     Flux checking  The differential pressure flowmeter sense smoke pipeline flow speed , provide basis for the control of fan speed
     Light transmittance  photocell sense the smoke density during the flaming
     Height of flame  Infrared visible light show the current height of the flame real-time
     Special software  Draw up the curve by the pip flow, smoke density, height of the flame ,and form a table automatically, through the printer printing
     Control system  5.7inch color touch screen, PLC from Japanese Panasonic, SCM, 16 bits high-performance AD transform etc

    Product introduction of the UL Cable Vertical-Tray Flammability Tester

    Apply to check the vertical-tray fire test for determining values of cable flame propagation and smoke release when the cables are subjected to a flaming ignition source. (It is nothing to the purpose of cables, such as the electric power, telecommunications etc.)

     Main components

    Main consist of Ignition source & supply fire control system, collection hood & exhaust duct flux control system, pressure measurement instrumentation of gas, smoke measurement instruments & temperature measurement system, flame height measurement system etc.

     Standards

    According to the clause 9.6 & 9.7 of UL1685-2007, UL2556-2007

    How are fire protection products tested?
    Many fire tests are run by official laboratories for the purpose of product certification. However, some manufacturers of fire protection products also maintain their own facilities and run tests for R & D purposes before going to the expense and exposure of a test at a third-party facility.

    What is UL 1685?
    UL 1685 is a smoke-release test for electrical and optical-fiber cables to determine their flame growth and smoke characteristics, which qualify them for limited smoke marking.

    UL1685-Vertical-Tray-Test-Enclosure





  • Previous:
  • Next:

  • Write your message here and send it to us
    industrial sewing machine