SL-FL69 Oxygen Index Tester (Electrochemistry)
ASTM D2863 Oxygen Index Tester (Electrochemistry) with Building Materials
Product introduction of Oxygen Index Tester (Electrochemistry)
The sample is placed vertically in a quartz glass cylinder filled with oxygen and nitrogen. The sample is usually ignited from the top and the combustion state of the sample is observed at the same time. If the material is continuously burning, whether the combustion can be maintained for 600 seconds is observed, and whether the flame spread distance reaches the required distance of the standard. In the process of testing, users need to constantly find the percentage concentration of oxygen which can maintain the continuous combustion, as the final detection results
Performance characteristics of Oxygen Index Tester (Electrochemistry)
1. According to the technology of oxygen sensor, the percentage concentration of oxygen can be obtained automatically, which is easy for users to read directly.
2. Digital display of nitrogen gas flow rate and the total flow rate of oxygen and nitrogen mixture. According to the test standard, the test needs to be carried out under the total flow rate of about 10.6L/Min.
3. Using precise metering gas flow valve to regulate gas flow, the accuracy of the whole instrument can reach the regulation range of 0-0.1L/Min, the current gas flow can be obtained more accurately, and the whole oxygen percentage step can be adjusted to 0-0.2 readings.
4. Equipped with electrochemical sensors, the external replacement mode of the chassis is convenient for users to replace.
5. Equipped with high temperature resistant quartz glass cylinder, it can withstand higher test temperature.
6. Equipped with gas igniter device, it can easily adjust the flame length and cut off the burning gas.
Product parameters of Oxygen Index Tester (Electrochemistry)
Application fields: building materials, rail transit, wire and cable, software furniture, automobile interior decoration
Size | 420 mm (W) x 350 mm (D) x 560 mm (H) |
Weight | 9kg |
Electrical | 220V, 10A |
Ambient Temperature | Operating 10°C to 35°C. |
Gas Supplies | Oxygen、Nitrogen |
Standards | ASTM D2863, ISO 4589-2:1996, NES 714 |
Applications | building materials, rail transit, wire and cable, software furniture, automobile interior decoration |