UL94 Horizontal and Vertical Flame Chamber
UL94 Flame Chamber for Test Measures the Burning Rate of Samples Positioned
Product introduction of the UL94 Flame Chamber
The test is widely applied throughout industry, especially in electrical manufacturing, where it is widely used for the testing of electrical products. The test measures the burning rate of samples positioned either horizontally or vertically.
Product parameters of the UL94 Flame Chamber
Kinds | 500W(5V class ) | 50W(HB/Vclass) |
Test Flame | 500W(burning test for V-0,V-1,V-2 classification) | 50W(burning test for V-0,V-1,V-2 classification) |
Burner Tube | Internal diameter: Φ 9.5mm±0.3mm | Internal diameter: Φ 9.5mm±0.3mm, |
Burning Angle | 0°,20°,45° | 0°,20°,45° |
Thermocouple | Type K (Ni/Cr - Ni/Al) | Type K (Ni/Cr - Ni/Al) |
Thermocouple Size | 0.5 mm | 0.5 mm |
Standard Copper Block | 9mm±0.01mm, weight:10g±0.05g before drilling. |
5.5mm±0.01mm, weight:76g±0.01g before drilling. |
Time for Temperature to Increase | From 100°C±5°C to 700°C±3°C; 54s±2s (preset) | From 100°C±5°C to 700°C±3°C; 44s±2s (preset) |
Gas Flow | 965±32ml/min | 105±10ml/min |
Gas Supply | methane,min.98% purity | methane,min.98% purity |
Water-column | 125m±5mm | ‹10mm |
Test Time | 54±2s | 44±2s |
Flame Height Indicator | 40±1mm | 20±1mm |
Volume Of Chamber | >0.5m³, black interior | >0.5m³, black interior |
Conform to standard | UL94,IEC60695-11-3,IEC60695-11-20 | UL94,IEC60695-11-4,IEC60695-11-10 |
Product Feature and Application of the UL94 Flame Chamber
1.The test chamber volume is greater than 0.75 cubic meters, and the inner wall of the box is black;
2.Ultra-large transparent observation window for easy observation of the combustion state of the sample;
3.User-designed door opening method for easy access to specimens and burners;
4.The burner angle can be easily adjusted at 0, 20, 45 degrees to meet the needs of various standards;
5.Provide Bunsen burner source, in accordance with ASTM D5025 standard;
6.The panel timer device can record information such as test time;
7.Providing a rotameter to regulate the flow of combustion gases;
8.High-precision pressure regulating valve to adjust the standard gas pressure required;
9.Fan burner, in accordance with ASTM D4986;
10.A top exhaust device that extracts exhaust gas generated by combustion;
11.Optional burner calibration system is available to ASTM D5207.
Product Details of the the UL94 Flame Chamber
The UL94 horizontal vertical burner adopts the full standard satisfaction design concept and considers many test standards and is integrated into one test box. The horizontal vertical burner is designed to test the UL standard flammability performance of equipment and appliance parts materials. Test indicators for end use such as flammability, burning rate, flame spread, burning strength and flame retardancy of the product can be tested.
It conforms to all five UL 94 horizontal and vertical burner tests and associated ASTM international standards. There are:
Horizontal Burning Test; UL 94HB (ASTM D 635, IEC 60695-11-10, IEC 60707, ISO 1210).
Vertical Burning Test: UL 94 V-0, V-1, or V-2 (ASTM D 3801, IEC 60695-11-10, IEC 60707, ISO 1210).
Vertical Burning Test: 5VA or 5VB (ASTM D 5048, IEC 60695-11-20, IEC 60707, ISO 9772).
Thin Material Vertical Burning Test: VTM-0, VTM-1, or VTM-2 (ASTM D 4804, ISO 9773).
Horizontal Burning Foamed Material Test: HF- 1, HF-2 or HBF (ASTM D 4986, ISO 9772).
Burners (ASTM D 5025, ASTM D 5207, ISO 10093, ISO 103351)
Standards:ISO:ISO 9772,ISO 9773 IEC:IEC 60695-11-10:2013 UL:UL94
Dimension:950 mm (W) x 850 mm (D) x 1350 mm(D)
Weight:58kg
Installation requirements
Electrical: 110V AC 60Hz / 230V AC 50Hz
Ambient Temperature: Operating 10°C to 35°C
Gas Supplies: Propane Gas or Methane Gas